Supplementary Material (Data): Experimental Validation of Design and Operation for Resilience of Water Distribution Systems

datacite.relation.isSupplementTo https://doi.org/10.15131/shef.data.29921033
dc.contributor.author Logan, Kevin
dc.date.accessioned 2026-03-05T15:33:02Z
dc.date.created 2026-03-05
dc.date.issued 2026-03-05
dc.description This dataset contains the experimental results of the validation study presented at the 21st International Computing & Control in the Water Industry Conference in Sheffield in September 2025. 24 separate cases were considered. The dataset contains one hdf5 file for each case with ten measurement runs each. The experimental configuration of each case is stored in the hdf5 files along with the measured values. For analysing the measured data, several resilience metrics are evaluated. The results are stored in the file data_250623_CCWI_Sheffield_evaluated_measurement_campaign.pkl. Two JSON files, eval_config.json and campaign_eval_config.json contain metadata relevant for the analysis. The JSON file parameter_mapping.json contains a mapping from the measured variables to the UUID of the sensor with which it was measured. Semantic digital data sheets for sensors and valves can be found under https://git.rwth-aachen.de/fst-tuda/public/metadata/fst_measurement_equipment/<UUID> and https://git.rwth-aachen.de/fst-tuda/public/metadata/fst_valves/<UUID> respectively.
dc.identifier.uri https://tudatalib.ulb.tu-darmstadt.de/handle/tudatalib/5051
dc.language.iso en
dc.rights.licenseCC-BY-4.0 (https://creativecommons.org/licenses/by/4.0)
dc.subject water distribution systems
dc.subject resilience
dc.subject experimental validation
dc.subject.classification 4.41-01
dc.subject.classification 4.22-04
dc.subject.classification 4.51-02
dc.subject.ddc
dc.subject.ddc 620
dc.subject.ddc 710
dc.title Supplementary Material (Data): Experimental Validation of Design and Operation for Resilience of Water Distribution Systems
dc.type Dataset
dcterms.accessRights openAccess
person.identifier.orcid 0000-0001-5512-2679
tuda.agreements true
tuda.project LOEWE center emergenCITY [LOEWE/1/12/519/03/05.001(0016)/72]
tuda.unit TUDa

Files

Original bundle

Now showing 1 - 20 of 28
NameDescriptionSizeFormat
arima_coupled_blockage_constant_system_1.hdf515.38 MB Download
arima_coupled_blockage_cosine_system_1.hdf515.51 MB Download
arima_coupled_no-disruption.hdf516.73 MB Download
arima_coupled_pump_outage_system_1.hdf515.78 MB Download
arima_decentral_blockage_constant_system_1.hdf513.6 MB Download
arima_decentral_blockage_cosine_system_1.hdf513.6 MB Download
arima_decentral_no-disruption.hdf513.57 MB Download
arima_decentral_pump_outage_system_1.hdf513.9 MB Download
dtw_coupled_blockage_constant_system_1.hdf513.85 MB Download
dtw_coupled_blockage_cosine_system_1.hdf513.7 MB Download
dtw_coupled_no-disruption.hdf513.6 MB Download
dtw_coupled_pump_outage_system_1.hdf514.21 MB Download
dtw_decentral_blockage_constant_system_1.hdf511.86 MB Download
dtw_decentral_blockage_cosine_system_1.hdf511.96 MB Download
dtw_decentral_no-disruption.hdf511.98 MB Download
dtw_decentral_pump_outage_system_1.hdf512.18 MB Download
pid_central_blockage_constant_system_1.hdf510.8 MB Download
pid_central_blockage_cosine_system_1.hdf510.69 MB Download
pid_central_no-disruption.hdf510.22 MB Download
pid_central_pump_outage_system_1.hdf510.7 MB Download

Collections